Simons Voss Technologies Palm LDB Version 1.40 Installationshandbuch Seite 198

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 318
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 197
VdS Shunt lock function 3066
Page 11
+
8
..16 V
Masse
+LED
- LED
C
NC
N0
SAB0
SAB0
SAB0
SAB0
2.3 Installing the Master Activation Unit (MA)
Soldering terminal assignments:
1 Supply voltage positive pole
2 Supply voltage negative pole (ground)
3 + 4 Connection for LED (5 volts) in outside area
5 - 7 Floating contacts for switching the alarm system
8 - 11 Sabotage contacts
12 Activation request from slave activation units (SAs) (optional)
13
Deactivation acknowledgement (input)
Activation suppression when ground is
applied
14 Deactivation request (output)
15 Ground (identical to soldering terminal 2)
29 Acoustic activation acknowledgement by BAC (not for DA)
30 Solder terminal for cable screen
Jumper settings:
Jumper connects right and middle contacts of B1:
Acoustic acknowledgement after activation release by activation unit
Jumper connects left and middle contacts of B1:
Acoustic acknowledgement after final activation is done by the BAC
(this is the VdS-compliant configuration).
Seitenansicht 197
1 2 ... 193 194 195 196 197 198 199 200 201 202 203 ... 317 318

Kommentare zu diesen Handbüchern

Keine Kommentare